TEMPERATURE |
Indicators
Single Display
ON-OFF / Prop ContSingle Display
Dual Display
PID ControllersSingle Display
Dual Display
Accurate |
Software linearized using multiple NIST inverse polynomials and Steinhart & Hart equation involving floating point arithmetic ensures a very high accuracy.
Autotuning |
The Gain, Integral Time, Derivative Time can be automatically set by running the Autotuning.
Alternatively they can be manually set.
Field configuration |
Completely Field selectable. Important parameters like sensor selection, Heat/Cool mode, Hyssteresis etc., can be selected in the field. There are no jumpers or presets.
Die hard |
Rugged linear power supply to handle the worst power condictions.
State of the art |
Advance single chip design.
Reliable |
No presets and jumperless design.
SPECIFICATIONS | ||||
Model | PID2x Series | |||
Power Supply | 220 VAC ± 15%. 50 / 60 Hz | |||
Power mConsumptiuon | Approx 1.5 VA | |||
Display | Dual 4 Digit Seven Segment LED Display. | |||
Display Size | ||||
PID2x 96 | Main | 0.56" RED | ||
Aux | 0.56" GREEN | |||
PID2x 72 | Main | 0.56" RED | ||
Aux | 0.39" GREEN | |||
PID2x 48 | Main | 0.39" RED | ||
Aux | 0.27" GREEN | |||
Sampling Time | 0.1 Sec | |||
Update rate | 2.5Hz | |||
Input Sensor | Universal Sensor Input | |||
Thermocouple | J, K | |||
R.T.D | DIN Pt100 | |||
Sensor Adj. | Zero Adjust. | Adj. -19.9 to 99.9°C. | ||
Linearisation | Thermocouple | Multiple Inverse Polynomials NIST |
||
R.T.D | Using Steinhart & Hart Equation. |
|||
Setpoint Range | Adj from front keys upto HSP. | |||
HSP (High setpoint Clamp) | Adj within Sensor operating range. | |||
Setpoint1 Control | HEAT | ON-OFF | ||
PID | ||||
COOL | ON-OFF | |||
Setpoint 2
Only Model: PID22 & PID23 |
Can be independently configured as:
|
|||
Setpoint 3
Only Model:PID23 |
Same as "Setpoint 2" | |||
Output | Relay Contact | 250 VAC, 5Amps | ||
SSR Output | 12 VDC ± 3V @ 20mA | |||
Display Accuracy. | ± 0.2% based on F.S or 3°C Max | |||
Resolution | Thermocouple | 1°C. | ||
R.T.D | 0.1°C | |||
Open Sensor Detect. | Displays "OPEN" and output is cut off. | |||
Setting type | Setting by front buttons. No Jumpers. | |||
ON-OFF Mode | Hysteresis | Adj. from 0.2 - 99.9°C at ON/ OFF Control | ||
PID Mode | AUTOTUNING | Initiated by user during instrument operation. | ||
Gain | Adj. 1 to 199.9 | Set automatically on
AUTOTUNING |
||
Integral Time | Adj 10 to 5000 | |||
Derivative Time | Adj. 0 to 500 | |||
Control | By duty cycle modulation. | |||
Cycle time | Adj. 1 -250 Sec. | |||
ON Duty (Min) | 5% of Cycle time. | |||
Ambient Temperature | 0°C - 45°C (non- freezing status) | |||
Humidity | 35 - 85% RH. |
Sensor |
3 Display Model |
4 Display Model |
||
Min |
Max |
Min |
Max |
|
RTD |
||||
DIN Pt100 |
-99°C |
660°C |
-160°C / |
660.0°C / |
J |
-99°C |
870°C |
-99°C |
870°C |
K |
-99°C |
999°C |
-99°C |
1300°C |
Model | No of Outputs | No of Displays | Size |
PID21 96 | 1 | 4+4 | RP-96x96 |
PID22 96 | 2 | ||
PID23 96 | 3 | ||
PID21 72 | 1 | 4+4 | RP-72x72 |
PID22 72 | 2 | ||
PID21 48 | 1 | 4+4 | RP-48x48 |
PID22 48 | 2 |